Aerobika® Oscillating Positive Expiratory Pressure Therapy System
Product Highlights
Combines Oscillatory PEP and nebulizer treatments.
Thins and dislodges mucus for easier clearance.
Aids in lung hygiene and prevents infections.
Requires less time than traditional chest physiotherapy.
Free 1-3 day shipping on orders $49+
30-day hassle-free returns.
Real Reviews from 40k+ satisfied customers
Aerobika® Oscillating Positive Expiratory Pressure Therapy System
Simplify your respiratory therapy routine with the Aerobika OPEP Therapy System from Monaghan Medical. This innovative device combines Oscillatory PEP and nebulizer treatments into a single, user-friendly solution. By creating brief bursts of increased expiratory resistance, the Aerobika helps to loosen and remove mucus, improving lung function and reducing the risk of infection. Its compact design and ease of use make it suitable for all patient groups, ensuring effortless compliance.

Features & Benefits
- Combines Oscillatory PEP and nebulizer treatments
- Reduces therapy time and facilitates compliance
- Thins and dislodges mucus for easier clearance
- Aids in lung hygiene and prevents infections
- Improves gas transfer and reduces air trapping
- Requires less time than traditional chest physiotherapy
- Easy to learn and use independently
How to disassemble your Aerobika® PEP Therapy Device
- Press the Attachment tables on either side of the device. Holding the tabs in, gently pull up on the case until the two parts separate.
- Remove the valve cartridge. DO NOT disassemble any part of the cartridge.
- To remove the mouthpiece, grip firmly and rotate while pulling away from the device.

How to clean your Aerobika® PEP Therapy Device
Designed for 12 months of use in the clinic, hospital or at home; Aerobika® OPEP therapy machine is dishwasher safe and designed for correct reassembly.
Soap and water
- Wash the four parts in a solution of lukewarm clean water and liquid soap detergent, allowing the parts to soak for 15 minutes. Agitate gently.
- Rinse in warm water.
- To dry, shake the parts to remove any excess water. Allow parts to air dry thoroughly before you put the parts back together.
Dishwasher
- The four disassemble parts may be washed in a dishwasher by securing parts in a basket on the top rack. Wash in a normal wash cycle with dishwasher detergent.
- If excess water remains, shake the parts and allow to air dry thoroughly before reassembling.
- Dishwashing with overly dirty dishes in not recommended.
These are abbreviated instructions for use, please remember to read the complete instructions that are packaged with your device.
| Nebulizer design | Handheld |
| Nebulizer technology | Other |
| Power source | Manual |